NMEA 2000 Cable & T Connector Connection Kit for Siren 3 Pro
Optimize the connectivity of your Connected Boat® system, allowing you to monitor engine data, water, fuel and waste tanks, and more! The NMEA 2000 Connection Kit includes a 2-meter connection cable and a 3-Way Connection "T" – everything you'll need to hook up to the NMEA 2000 data system 'backbone'.
*Compatible with the Siren 3 Pro Only
Specifications:
- Data Interface: NMEA 2000
- NMEA 2000 Connectors: Backbone/Drop Cables
- Box Dimensions: 1"H x 7"W x 7"L WT: 0.45 lbs
- UPC: 857331007518
NMEA2000 Mid Bulk Cable Reel - 100M
This cable can be used to create or extend an NMEA 2000® network of flexible lengths to suit any installation. The cable is ideal for use with any of the Actisense A2K Product range for building networks.
The cable is LSZH certified to give installers and end users maximum peace of mind and an extra layer of safety.
The Actisense range of NMEA 2000® connectors and cables has been designed using our specialist interconnectivity and NMEA knowledge. All Actisense cables and connectors are NMEA 2000® approved.
The NMEA 2000® cable includes five wires within a single waterproof cable: power and ground wires, two signal wires, and a drain wire. The drain wire connects to the cable shield, which protects the signal, power, and ground wires from external Radio Frequency Interference (RFI) and helps reduce RFI emission from the cable.
NMEA 2000® Mid cable can be used to create a backbone up to 250 meters in length, and offers a current capacity of 4A with Micro connectors, or 8A with Mini connectors.
Technical Specifications:
Cable
- Rated Voltage - 60V DC
- Rated Current - 8A
- Braid Material - 37 AWG tinned copper
- Braid Coverage - 65% Nom.
- Jacket Material - LSZH Purple (RAL4008)
- Jacket Outer Diameter - 8.2mm
- Overall DCR (braid + tape + drain) - 3.2Ω / 1000ft (10.5mΩ/M)
- Reel Length - 100m
- Reel Weight - 13-14kg
Power Pair
- Conductor - 16 AWG (19-strand tinned copper)
- Insulation - 0.17 mm Nom. LSZH
- Diameter - 1.85mm Nom.
- Colors - Red & Black
- Shield - AL Mylar tape over pair
- DC Resistance - 4.26Ω / 1000ft (14mΩ/M)
Data Pair
- Conductor - 20 AWG (19-strand tinned copper)
- Insulation - 0.79 mm Nom. Foam PE
- Diameter - 2.49mm Nom
- Colors - Blue & White
- Shield - AL Mylar tape over pair
- Impedance - 120Ω ±10% @ 1MHz
- DC Resistance - 10.9Ω / 1000 ft (35.8mΩ/M)
- Attenuation @ 125 kHz - 0.29dB / 100ft
- Attenuation @ 500 kHz - 0.50dB / 100ft
- Attenuation @ 1 MHz - 0.70dB / 100ft
Drain
- Conductor - 20 AWG (19-strand tinned copper)
- DC Resistance - 10.9Ω / 1000ft (35.8mΩ/M)
Approvals and Certifications
- Operating Temperature - -20°C to +70°C
- Storage Temperature - -40°C to +85°C
- NMEA 2000 Approved
- RoHS Compliant
- UL Certified (E137250), (UL13)
- LSZH to IEC 60754-1/2 & IEC 61034-1/2
Specifications:
- Data Interface: NMEA 2000
- NMEA 2000 Connectors: Backbone/Drop Cables
- Box Dimensions: 12"H x 14"W x 14"L WT: 30 lbs
- UPC: 5060998710812
Brochure (pdf)
PRO NMEA 0183 Multiplexer/NMEA 2000 Gateway
Interconnectivity, reimagined!
The PRO-NDC-1E2K is much more than an NMEA 0183 Multiplexer…
Rugged, Robust, Type Approved Multiplexer with built-in NMEA 2000 connectivity, high-speed Ethernet streaming of data, flexible configuration, auto-switching and sentence level filtering.
Managing and routing your NMEA data is straight forward, hassle free using the PRO-NDC-1E2K
Features:
- Auto-switching between inputs to allow for a primary, secondary, tertiary priority input.
- Configurable baud rates to allow 38400 and 4800 baud devices to operate through the same multiplexer.
- Sentence filtering to block unwanted sentences from specific outputs helps to limit bandwidth consumption.
- Easy to configure using the web based UI, no need to manually enter and edit strings of text.
- RINA type approved device means the multiplexer is fit for leisure, commercial and class / type installations.
- Multiple LED’s allow for ‘quick glance’ diagnostics to ensure everything is operating correctly.
- Certified NMEA 2000 device connectivity allows for conversion and output of data onto NMEA 2000 network.
- Bi-directional conversion to and from N2K Network allows for seamless integration between legacy and new equipment.
- NMEA 0183 data streaming over Ethernet enables connectivity to existing Ethernet devices and systems.
- NMEA 2000 data streaming over Ethernet.
- 5 OPTO-Isolated NMEA 0183 inputs and 2 ISO-Drive NMEA 0183 outputs provide protection for all connected instruments.
- Type-approved (RINA).
- NMEA 0183 Ethernet streaming
- NMEA 2000 Ethernet streaming
- NMEA 2000 output via M12
- 5x Configurable Opto-isolated NMEA 0183 inputs.
- 2x Configurable ISO-Drive isolated NMEA 0183 outputs.
- 1x Bi-directional, configurable, isolated serial port.
- Automatic baud rate matching on inputs.
- Advanced data filtering / routing.
- Free firmware updates making the device future-proof.
- Diagnostic LEDs on all inputs and outputs.
- Bi-colour status LED.
- Panel mountable.
- Stainless Steel housing for added durability
- Quick and easy to install
- Configuration using standard web browser, no PC operating system compatibility issues
- Advanced features solve NMEA 0183 data routing problems
- Fully isolated with ISO-Drive technology for peace of mind
- Easy firmware updates make the device future-proof
- Type Approved (RINA)
Technical Specifications:
Power Supply
- Input supply voltage - 9 to 35 V DC
- Input supply current - 150mA max @ 12V DC (all outputs @ full drive into 100 ohm loads)
- Input protection - Continuous reverse polarity, transient overvoltage and ESD protection
- Power indicator - LED, Blue – indicates unit is functioning correctly
- Input Supply connector - Pluggable 2-way screw terminal, 5.08mm pitch (12 to 30 AWG)
NMEA 0183 Port – Listener & Talker
- Number of Listener / Input Ports - 5 isolated NMEA 0183 Listeners
- Number of Talker / Output Ports - 2 isolated NMEA 0183 Talkers
- Compatibility - Fully NMEA 0183, RS422 & RS232 compatible. RS485 Listener compatible
- Speed / baud rate - 4800 to 38400 bps
- Talker Output Voltage Drive - >= 2.2V (differential) into 100 ohm
- Talker Output Current Drive - 20 mA maximum per output
- Talker Output Protection - Short circuit and ESD
- Talker Data Indicator - LED, Orange (Flashes with data rate)
- Listener Input Voltage Tolerance - -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
- Listener Input Protection - Current limited, overdrive protection to 40 VDC and ESD protection
- Listener Data Indicator - LED, Green (Flashes with data rate)
- Connectors - Pluggable 2/3 way screw terminals, 5.08mm pitch (12 to 30 AWG)
Serial Port
- Compatibility - RS422 & RS232 compatible. RS485 Listener compatible
- Speed / baud rate - 115200 bps
- Output voltage drive - >= 2.1V (differential) into 100 ohm
- Output current drive - 20 mA max.
- Output protection - Short circuit and ESD
- Input voltage tolerance - -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
- Input protection - Current limited, overdrive protection to 40 VDC and ESD protection
- Data Indicators - LED’s: Green = Receive, Orange = Transmit
- Connectors - Pluggable 3-way screw terminals, 5.08mm pitch (12 to 30 AWG)
Ethernet Port
- Host interface - 10/100BaseT, automatic polarity detection
- Supported protocols - TCP/IP for configuration and firmware updating, TCP/IP and UDP for NMEA 0183 comms
- Connector - RJ45
- Indicators - Green – Link, Yellow – 100 Mbps
NMEA 2000 Port
- Compatibility - NMEA 2000 Certification Pending
- Speed / baud rate - 250 kbps
- Connectivity - M12 male (A-coded) connector
Isolation
- NMEA 0183 Listener - Uses IsoDriveTM, Hi-Pot tested to 1000V
- NMEA 0183 Talker - Uses IsoDriveTM, Hi-Pot tested to 1000V
- Serial Port - Uses IsoDriveTM, Hi-Pot tested to 1000V
- Ethernet Port - 2kv for 60s
- NMEA 2000 Port - OPTO-Isolated, Hi-Pot tested to 1000V
Mechanical
- Housing Material - 316 Stainless Steel
- Dimensions - 139mm (W) x 98mm (H) x 26mm (D)
- Weight - 360g
- Mounting - Bulkhead mount or DIN rail mount (DIN kit 1)
Approvals and Certifications
- EMC - IEC 60945:2002-08, DNVGL-CG-0339:2019 & IACS UR E10 Rev7
- Compass Safe Distance - 300mm
- Type Approval Certificate - RINA
- Operating Temperature - -25 to +70°C
- Storage Temperature - -40 to +85°C
- Relative Humidity (RH) - 95% @ 55°C
- Environmental Protection - IP40
- Guarantee - 5 Years when registered
Specifications:
- Data Interface: NMEA 0183
- Box Dimensions: 2"H x 6"W x 10"L WT: 1.05 lbs
- UPC: 5060998710751
Quick Guide (pdf)
Owner's Manual (pdf)
Brochure (pdf)
Maretron IPG100 Internet Protocol Gateway [IPG100-01]
IPG100 (Internet Protocol Gateway) lets you connect Maretron black boxes (MBB100's), Maretron touch screens (DSM800's), PC's, Mac's, tablets, or smartphones to an NMEA 2000 network so you can monitor and control your vessel using Maretron's N2KViewr software. The conventional way of viewing NMEA 2000 information is with a display on the vessel that is directly connected to an NMEA 2000 network, but with the IPG100, you are not limited to direct connected displays. With the IPG100, you can use any device running N2KViewr software to monitor and control your vessel from onboard or ashore.
Fuel Flow Sensor - 25-500 LPH/6.6-132 GPH
Features:
- Operating Temperature: -40°C to 80°C (-40°F to 176°F)
- Storage Temperature: -65°C to 170°C (-85°F to 338°F)
- Port Size: 1/4" NPT Female
- Cable Length: 1M (3.28 ft)
- Maximum Viscosity: 1000 cPs
- Pressure: 68.95 Bar (1000 PSI)
- Strainer Size: 200 Mesh (If not already installed after fuel filter)
Actisense NMEA 2000 Engine Monitoring Unit - Analog to NMEA2000 Engine Gateway [EMU-1-BAS]
Actisense NMEA 2000 Engine Monitoring Unit - Analog to NMEA2000 Engine Gateway [EMU-1-BAS]
NMEA 2000 Engine Monitoring Unit - Analog to NMEA2000 Engine Gateway
Share engine information on the NMEA 2000 bus.
The Actisense EMU-1 is a specialized analogue to NMEA 2000 Gateway which converts data from analogue engine gauges/senders into NMEA 2000 data. The EMU-1 enables the sharing of engine data throughout the NMEA 2000 bus. It digitizes analogue engine sensors, enabling NMEA 2000 display devices to monitor the connected engine(s) on a vessel.
The EMU-1 can monitor vital engine parameters such as temperature, pressure RPM and fluid levels from up to two engines.
The EMU-1 has a PC-based configuration tool that allows the settings inside the EMU-1 to be changed to best suit the engine it is working with, making it a flexible solution for many engine makes and models.
An Actisense PC to NMEA 2000 Gateway (NGX-1/NGT-1) is required to configure the EMU-1.
The NGX-1 or NGT-1 must be used to update the firmware, connect the Toolkit and display data on a PC for diagnostic and information purposes, using NMEA Reader. Please visit the NGX-1 page and/or NGT-1 page for product details.
Features:
- Enables analogue signals to be converted to NMEA 2000 messages
- Convert signals from up to two engines (that share a common ground) with a single EMU-1
- 6 gauge / parameter inputs
- 4 alarm inputs
- 2 additional auxiliary inputs
- 2 Tacho inputs
- Customized IP65 case
- Diagnostic LED’s
- Wide power compatibility of 9 to 35VDC
- No need to change an existing engine
- Easy installation
- Easy to configure to suit the connected engine
- Connect signals from fluid level gauges (that share a common ground with the engine) to NMEA 2000®
- Optional DIN rail mounting kit available
- Total engine hours are logged by the monitoring of engine Tach (RPM) input
Technical Specifications:
Power Supply
- Supply Voltage - 9 to 35VDC
- Supply Current - Typically < 25mA @ 12VDC
- Supply Protection - Continuous reverse polarity protection and load dump protection (meets SAE J1113)
- Supply Connector - Pluggable 2-way screw terminal, 3.5mm pitch
- Supply Voltage (NMEA 2000 Port) - 9 to 29VDC
- Supply Current (NMEA 2000 Port) - < 20mA @ 12VDC from NMEA 2000 bus
- Load Equivalent Number (LEN) - 1
- Supply Protection (NMEA 2000 Port) - Continuous reverse polarity protection and overvoltage protection to 40V
NMEA 2000 Port – In/Out
- Compatibility - Fully NMEA 2000 certified
- Galvanic Isolation - 2500V input to ground, 1500V output to ground using ISO-Drive
- Speed / Baud Rate - 250kbps
- NMEA 2000 Connector - M12 male (A coded) connector
Gauge Inputs
- Voltage Range - 0 to 35VDC
- Input Impedance - > 50kΩ
- Sender Feed - 0, 4 or 18mA
- Accuracy - <= 2%
- Input Connector - Pluggable 6-way screw terminal, 3.5mm pitch
- Input Protection - Overvoltage protection to ±40V
Alarm Inputs
- Voltage Range - 0 to 37VDC
- Input Impedance - > 50kΩ
- Threshold Voltage - Configurable, default is 5V
- Alarm Polarity - Configurable, default is alarm on low input
- Accuracy - <= 2%
- Input Connector - Pluggable 4-way screw terminal, 3.5mm pitch
- Input Protection - Overvoltage protection to ±40V
Tacho Inputs
- Voltage Range - ±3 to ±60V
- Input Impedance - > 100kΩ to ground
- Input Pulse Range - 4 to 50,000Hz
- Accuracy - <= 1%
- Sender Compatibility - Ignition coil, alternator (“W”, “R” or “AC”) terminal, hall effect, VR or inductive sender
- Threshold - Automatically adjusts to signal level
- Input Connector - Pluggable 4-way screw terminal, 3.5mm pitch
- Input Protection - Can withstand an ignition pulse to ±500V
Engine Log
- Engine Hours - 2 separate engine hour logs internally connected to the tacho Inputs. Hours are logged when RPM is present, stored in non-volatile memory
Mechanical
- Housing Material - Polycarbonate
- Protective Lid Material - Polycarbonate
- Sealing Materials - Expanded silicone foam gasket, closed cell polyurethane splash guard and ePTFE waterproof vent
- Dimensions - 127mm (L) x 112mm (W) x 48mm (H)
- Weight - 250g
- Mounting - 4 x 3.5mm lugs to allow panel mount with self tapping s/s screws (included), optional DIN Rail mount available on request
Approvals and Certifications
- EMC - EN 60945 (sections 9 & 10)
- Environmental Protection - IP66 (PCB housing)
- Operating Temperature - -20°C to +55°C
- Storage Temperature - -30°C to +70°C
- Recommended Humidity - 0 – 93% RH
- Guarantee - 3 years
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.
Specifications:
- Data Interface: NMEA 2000
- Box Dimensions: 3"H x 6"W x 9"L WT: 1 lbs
- UPC: 5060998710331
Lowrance TR-120-KIT
Set of 1 male and 1 female NMEA 2000r7reg; terminators
Specifications:
- Data Interface: NMEA 2000
- Box Dimensions: 2"H x 3"W x 5"L WT: 0.08 lbs
- UPC: 042194533575
Airmar Noland RS11 Analog to NMEA 2000 Data Converter [RS11]
Noland RS11 Analog to NMEA 2000 Data Converter
The RS11 is intended for converting Tach and analog sensor data into NMEA 2000 messages for display by devices such as chart plotter MFDs (Multifunction Displays). The engine connections are made to existing gauges or directly to senders if there is no gauge. The RS11 can provide drive current to resistive senders where needed. Two RPM inputs plus six analog inputs on each RS11 means it can support one or two engines as needed.
Configuration and calibration of the RS11 are done with a Windows PC(via USB) and the supplied software. It consists of selecting the specific information(engine temp, oil press, etc.) to convert on each input and supplying proper calibration values. There are also options to turn on "Sender Current" where needed, enable or reset "Engine Hours", and set Alarm Values for some inputs. If software updates are ever needed, they are done with a Windows PC via USB.
A water-resistant housing protects the RS11 internal components, while a gasket cover seals the terminal strip connections to the engine. A plastic plug seals the USB Port when not in use. A multicolor status LED indicates the operating mode of the RS11. All inputs can handle 30V or more of applied voltage without damage.
Specifications:
- Supply Voltage/Current: 10-30 Vdc, 40 mA. max
- Pulse Input Impedance: 100K ohm
- Analog Input Impedance: 13K ohms
- Analog Input Accuracy: +/- 1%
- Operating Temp: -20 – 70 °C
- Humidity range: 0 – 100% (non-condensing)
- Certification: NMEA 2000 (Level A), LEN 1
- Size/weight: 2.4″ x 3.4″ x 0.9″ / 3 oz.
- Warranty: 3 year repair/replacement
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.